Insulation is one of the few plant upgrades that pays for itself purely through the energy it saves. The difficulty is proving it. An insulation energy audit turns “that line feels hot” into a number a finance team can approve.
Step 1: Survey the system
Walk the plant with an infrared camera and a contact thermometer. For each line or item of equipment, record:
- Process temperature and operating hours per year
- Pipe size and length, or equipment surface area
- Insulation type, thickness and condition
- Measured surface temperature and ambient temperature
Note every bare valve, flange and support. Uninsulated fittings are often the largest single source of heat loss on an otherwise insulated line.
Step 2: Calculate the heat loss
Heat loss per metre follows from the process temperature, the ambient conditions, the pipe size and the thermal conductivity and thickness of the insulation. ISO 12241 and ASTM C680 set out the calculation method. Run it twice: once for the existing condition and once for the proposed insulation.
Step 3: Turn heat loss into money
Annual saving = heat loss reduction (kW) × operating hours ÷ heater efficiency × fuel cost per kWh
Divide the installed cost of the upgrade by the annual saving to get the simple payback in years.
A worked example
The figures below are illustrative, not measured data, but they show how the calculation runs.
- 100 m of steam line with damaged insulation, losing 250 W per metre
- After re-insulation the calculated loss falls to 90 W per metre: a saving of 160 W per metre
- 160 W × 100 m = 16 kW saved
- 16 kW × 8,000 operating hours = 128,000 kWh of heat per year
- At 85% boiler efficiency that is about 150,600 kWh of fuel
- At a fuel cost of USD 0.04 per kWh, the saving is about USD 6,000 per year
If the upgrade costs USD 15,000 installed, the simple payback is 15,000 ÷ 6,000 = 2.5 years.
Step 4: Count the savings that are not on the fuel bill
- Lower CO2 emissions from the fuel that is no longer burned
- Safer surface temperatures for personnel protection
- More stable process temperatures
- Less risk of corrosion under insulation where wet insulation is replaced by a hydrophobic material
- Space freed where a thin aerogel build-up replaces a thick conventional one
Where aerogel changes the result
Wet or compacted insulation does not perform as its datasheet says, so the real loss is often higher than the design figure. Aerogel blankets are hydrophobic and do not slump, which keeps the installed performance close to the calculated one. And where space is tight, the same thermal resistance at a fraction of the thickness makes an upgrade possible on lines that cannot take thicker conventional insulation.
See our heat conservation applications, or request a free thickness calculation for the lines in your audit.